Conditions

Osteoarthritis
Slipped Capital Femoral Epiphysis
Congenital Hip Dysplasia
Collagen Disorders
Avascular Necrosis
Nonunion of Femoral Fractures
Post-traumatic Arthritis
Rheumatoid Arthritis

Treatments

Device: DePuy ASR™ Hip System
Device: DePuy ASR™ XL Head / ASR™ Acetabular Cup System

Study type

Interventional

Funder types

Industry

Identifiers

NCT00872547
CT05/18

Details and patient eligibility

About

The purpose of this study is to monitor the performance of a large metal-on-metal bearing from the DePuy ASR™ System in the treatment of patients with hip joint disease requiring hip resurfacing surgery or a total hip replacement. Patients who enter the study will be evaluated at regular intervals following hip surgery using patient, clinical and x-ray assessments.

The Study was terminated with effect from 30th November 2011 following the completion of 2 year follow up assessments for those patients remaining in the study.

Please note that prior to this decision DePuy voluntarily recalled the ASR products on 24 August 2010. Additional information regarding this voluntary recall and the follow-up of patients affected by the recall can be found at the following links http://www.mhra.gov.uk/Publications/Safetywarnings/MedicalDeviceAlerts/CON155761 and http://www.depuy.com/countries_list.

Enrollment

329 patients

Sex

All

Ages

18 to 65 years old

Volunteers

No Healthy Volunteers

Inclusion and exclusion criteria

General Inclusion Criteria:

i) Male or female subjects, aged between 18 and 65 years inclusive.

ii) Subjects who are able to give voluntary, written informed consent to participate in this investigation and from whom consent has been obtained.

iii) Subjects, who, in the opinion of the Investigator, are able to understand this investigation, co-operate with the investigational procedures and are willing to return to the hospital for all the required post-operative follow-ups.

Inclusion Criteria for DePuy ASR™ Resurfacing system:

i) Subjects with primary osteoarthritis indicated for standard MoM hip resurfacing arthroplasty with cementless fixation in the acetabulum.

Inclusion Criteria for ASR™ XL Head system:

i) Subjects whose bone morphology and bone quality mean that standard MoM hip resurfacing arthroplasty is not indicated, but for whom cementless fixation in the acetabulum and receipt of a large MoM bearing are still possible.

General Exclusion Criteria:

i) Subjects who, in the opinion of the Investigator, have an existing condition that would compromise their participation and follow-up in this study.

ii) Subjects with compromised renal function defined as those whose measured values lie outside the normal range for a particular investigational site.

iii) Subjects with proven metal sensitivity.

iv) Subjects with infectious, highly communicable diseases, which may limit follow-up i.e. Active tuberculosis, hepatitis, immuno-compromised conditions, etc.

v) Women who are pregnant or who intend to become pregnant within 2 years of surgery.

vi) Subjects who are known drug or alcohol abusers or with psychological disorders that could affect follow-up care or treatment outcomes.

vii) Subjects who have participated in a clinical study with an investigational product in the last 6 month(s).

viii) Subjects who are currently, or have been in the last 12 months, participating in a clinical study which involves exposure to ionising radiation.

ix) Subjects who are currently involved in any injury litigation claims.

x) Subjects who are undergoing corticosteroid treatment.

xi) Subjects with active or recent joint sepsis.

Additional Exclusion Criteria for DePuy ASR™:

i) Subjects with proven significant osteoporosis and poor bone quality.

ii) Subjects with marked atrophy or deformity in the upper femur, skeletal immaturity, or where loss of musculature or neuromuscular disease would render the procedure unjustifiable.

iii) Subjects whose anatomical CCD angle is below 120°.

iv) Subjects who have undergone irradiation of the affected hip.

Trial design

Primary purpose

Treatment

Allocation

Non-Randomized

Interventional model

Parallel Assignment

Masking

None (Open label)

329 participants in 2 patient groups

1
Active Comparator group
Description:
Resurfacing system
Treatment:
Device: DePuy ASR™ Hip System
2
Active Comparator group
Description:
Large Metal-on-Metal Total Hip Replacement
Treatment:
Device: DePuy ASR™ XL Head / ASR™ Acetabular Cup System

Trial contacts and locations

8

Loading...

Data sourced from clinicaltrials.gov

Clinical trials

Find clinical trialsTrials by location
© Copyright 2025 Veeva Systems